Changes are great, but if you want to undo an IDF modification and restore to the default, you need to follow these steps:

Reset to an Infor shipped view (“un-modify” it)

  1. Open the public node of an object you would like to reset to the shipped status. Notice that all of the standard views (i.e., those owned by Infor) are unmodified.
  2. Select the row with the Modified column = yes
  3. Select the Reset to default button on the toolbar
  4. Say Yes to the prompt
  5. The object is now back to the way it was shipped by Infor. Note that it now shows that it has not been modified. If you display the editor, you will see that the attribute you deleted has been restored. Note that only objects owned by Infor can be reset. If you change a standard definition, and later regret it, you can use this feature to restore it with a couple of clicks.
Previous Article How to Improve Customer Shipments With OTTO - A Case Study
Next Article Tax Law Changes by the Numbers - Infor LX & BPCS Integration to Avalara
Print
30900 Rate this article:
5.0
Anthony Etzel

Anthony EtzelAnthony Etzel

Other posts by Anthony Etzel

Theme picker

Contact author

Please solve captcha
x

Tips:  LX | BPCS | M3

The cycle counting sub-system in Inventory Management determines which items are selected for cycle counting based on the following criteria:

  1. Cycle Counts/Year: The system calculates the cycle count frequency for each item using the "Cycle Counts/Year" field in the Item Master file (optional).

  2. Last Cycle Count Date: If you use locations, this date is found in the Location Inventory file (ILI), and if you don't, it's in the Warehouse Inventory file (IWI).

The system adds the calculated cycle count frequency to the last...

WebTop release 4.8 is NOW AVAILABLE for Infor LX versions 8.3.5 and 8.4.x.

WebTop is a web interface based on green screen code automatically generated using a tool called 'WebTop Studio'. The process of generating the web interface is referred to as "Weblication".

Infor is focused on modernizing and web-enabling Infor LX and this release provides significant improvements to the web-based user experience.
Key features:

  • Grid decorators for advanced customization
First1516171820222324Last

Theme picker

Tips: LN | Baan

All actions required for converting, validating, matching, and posting electronically received bank statements can be performed within a single session:

  • Bank Statement Workbench (tfcmg5610m100)
  • Bank Statement (tfcmg5610m000)

Alternatively, you can use the sequence of electronic bank statement sessions outlined below.

Steps to Process Electronic Bank Statements:

1345678910Last

Theme picker

Categories