Infor LX & BPCS Tip of the Week: ION Tip – Pausing Receiving and Sending of Messages

If it is necessary to pause sending and receiving of BOD messages on your IBM i during your month-end process, it is best practice for the document flows that point to the IBM i to guarantee delivery of BOD messages. Once the month-end process has been completed, you will need to Resume the ‘Receiving’ and ‘Sending’ Active Connection Points so your documents will continue to process.

Pausing Sending messages

To pause sending messages to ION:

  1. Select Connect > Active Connection Points.
  2. Select the connection point that must be paused for sending messages.
  3. In the Sending Paused column, click Pause. The page is automatically refreshed and the Sending Paused checkbox is selected. A Resume button becomes available. 

Sending of messages by this connection point is stopped. No new messages are picked up from the source application's outbox. The connection point still processes messages that were already picked up from the outbox. This action can take some time in the background even though the sending status of the connection point is already changed to Paused. Any new message, that was published from an application after the sending of its connection point is paused, has not yet entered ION and is not yet available in ION OneView.

Pausing Receiving messages

To pause receiving messages from ION:

  1. Select Connect > Active Connection Points.
  2. Select the connection point that must be paused for receiving messages.
  3. In the Receiving Paused column, click Pause. The page is automatically refreshed and the Receiving Paused checkbox is selected. A Resume button becomes available.

Receiving messages by the connection point is paused.  No new messages are delivered to the destination application's inbox. All new incoming messages to this application are parked in its incoming pending messages queue inside ION.  The connection point still processes messages that were already picked up from the incoming pending messages queue. This action may take some time in the background even though the receiving status of the connection point is already changed to Paused.

Resuming sending / receiving messages

To resume sending or receiving messages from ION:

  1. Select Connect > Active Connection Points.
  2. Select the connection point that must be resumed for message processing.
  3. Select one of these actions:
    1. To resume the pickup of messages from an application outbox, click Resume in the Sending Paused column.
    2. To resume the delivery of messages to an application inbox, click Resume in the Receiving Paused column.

The page is automatically refreshed and, depending on the selected action, the Sending Paused checkbox or the Receiving Paused checkbox is cleared. A Pause button is now available.

Previous Article Tax Law Changes by the Numbers - Infor LX & BPCS Integration to Avalara
Next Article Infor LN & Baan Tip of the Week: Customer requested delivery date
Print
43260 Rate this article:
5.0
Anthony Etzel

Anthony EtzelAnthony Etzel

Other posts by Anthony Etzel

Theme picker

Contact author

Please solve captcha
x

Tips:  LX | BPCS | M3

Role-Based Security introduces Role type profiles and allows combining the use of Role profiles with the traditional LX User type security profile functionality. The new Role type profile can be defined to allow or deny access to All Products, Attention Key, Products, Programs, and Transaction Effects. Facility, Warehouse, and Company securities are still defined solely by the User profile settings and are not affected by the assignment of a Role. Where applicable, the Role authority is displayed alongside the User authority on the security profile maintenance screens making it easy to see where there are differences in authority between the User and the assigned Roles. 

When Users are assigned to Roles, security access in LX becomes a combination of authorities granted or denied by the Role, plus any User Exceptions. User Exceptions override authorities set by the Roles. A User can also be assigned to more than one Role.

12345678910Last

Theme picker

Tips: LN | Baan

Baan uses the company calendar in the following modules to determine the start and end dates for planned orders:

  • Master Production Scheduling
  • Material Requirements Planning
  • Capacity Requirements Planning
    (All three combined in a single planning module for Baan V and LN)
  • Shop Floor Control

The calendar provides the valid working days, number of shifts per day and the number of hours in a day.

Baan allows for a single calendar for the whole company or for a calendar for each work center.

Baan/LN Tip of the Week: GRINYA

GRINYA is one of the more complex issues in ERP Finance. GRINYA is the tracking via ledger account of the value of items received on a purchase order that have not been matched to a supplier invoice.

Baan solutions for Baan IV and V were incomplete. To take full advantage of the current GRINYA reconciliation process, check Infor solution #107147, which contains the GRINYA user manual and a link to download the software for your version of Baan. For ERP LN, look at Document Code U8942C US.

It is called User Guide for Reconciliation and Analysis. If you are not running the latest GRINYA solutions, patching will require a good amount of time in filling the Interim tables this solution runs from. Infor has posted several procedural write ups, so check the Support Site and read up before tackling this for the first time.